  1. Number:        A1TH083090U502 
  2. Subject:       Token-Ring Twisted Pair Must Have Six Twists per Foot 
  3. Date:          December 14, 1990
  4. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
  5.  
  6. PROBLEM:       A customer was using IBM Token-Ring and Proteon wire centers
  7.                with twisted pair.  When he would add a workstation to the
  8.                ring (making it an even number of workstations), the other
  9.                workstations would get slow response from the file server or
  10.                would loose connection to the network.  
  11.  
  12. SOLUTION:      Token-Ring must have six or more twists per foot for the
  13.                twisted pair wire.  They found out that the wire between
  14.                workstations and wire centers had only two twists per foot. 
  15.                They replaced the cable and the network now works fine. 
  16.   
  17.                This points out something.  Not every brand of cable that
  18.                says it is IBM type 1, 2, or 3 is truly compatible.  IBM has
  19.                some very stringent specifications and the AT&T premis
  20.                distribution specifications for type 3 are even more
  21.                stringent. 
  22.  
  23.                (X)    This information was verified verbally
  24.  